Are your
acoustic sensors working?
The
SW51 is a versatile test instrument designed to measure the input and output
levels of almost all subsea electro-acoustic devices. The PROBE can provide operators with
critical performance readiness criteria prior to deployment.
Check transponders, scanning sonars, pulse sonars, beacons, side-scan systems,
DP systems and many others where access to the transducer(s) is available.
The
SW51 will become a focal point for your preventative maintenance program and
save hours of test and evaluation time.
|
VERSATILE
-- PORTABLE -- STATE-OF-THE-ART
(call
or email for a quote: sales@sunwest-tech )
|
|

|
A
FEW OF THE SW51 FUNCTIONS
 |
Check
transmitter output at transducer. |
 |
Measure
band edge limits. |
 |
Measure
receive sensitivity. |
 |
Check
display function. |
 |
Interrogate
transponders and measure response. |
 |
Check
pinger/beacon output. |
 |
Observe
Doppler and AGC shift on Doppler systems. |
 |
Measure
"zero beat" frequency. |
 |
Pulse
rate, width, frequency, burst output
and CW.
|
|
|
SW51 will provide good repeatable measurements
when
properly used,
to support preventative maintenance
and repair programs. |
|
TRANSMIT
FREQUENCY |
0
Hz to 1.3 MHz in 1 Hz steps
May be extended to 2.5 MHz
with reduced battery life |
|
TRANSMIT
VOLTAGE |
Variable to 3.5 VRMS |
|
RECEIVE FREQUENCY |
5 kHz to 1.3 MHz in 1 Hz steps |
|
SIGNAL STRENGTH LINEARITY |
± 2 dB |
|
INSTANTANEOUS RECEIVER
DYNAMIC RANGE |
80 dB |
|
TOTAL RECEIVER
DYNAMIC RANGE |
110 dB |
|
RECEIVER NOISE LEVEL |
3 µV RMS in 4 kHz bandwidth |
|
RECEIVER DET SENSITIVITY |
3 µV to 5V range; 20 dB per volt |
|
TRANSMIT
PULSE WIDTH |
1 ms to 20 ms |
|
EXTERNAL SYNC DELAY |
10 ms to 500 ms |
|
PULSE RATE, INT MODE |
1 PPS to 50 PPS |
|
CASE SIZE |
10.5 in. L, 9.5 in. W, 4.75 in. H |
|
WEIGHT |
7 Lbs. |
|
BATTERY TYPE |
NiCd (5 'C' Pack) |
|
CASE TYPE |
Structural resin with purge valve |
|
WATER RESISTANT |
When closed |
|
PROBE SIZE
Model 30402 |
3.5 in. L, 0.88 in. Dia |
|
CABLE |
RG-58U with BNC Connector
4 Ft. Length |
|
HIGH FREQUENCY PROBE
(75 kHz to 1.3 MHz) |
P/N
30418 |
|
LONG CABLE PROBE
15 ft (Hi Freq)
15 ft (Std Freq) |
P/N 30418-15
P/N 30402-15 |
|
EXTRA BATTERY PACK |
P/N 30463 |
|
CUSTOM OPERATING PROCEDURES |
(Special Quote) |
|
PROBE
(J1) |
Acoustic Probe -
Transmit/Receive (BNC) |
|
SYNC
(J2) |
Ext Transmit trigger -
Int mode sync out (BNC) |
|
DETECT
(J3) |
Receive signal strength output (BNC) |
|
SIGNAL
(J4) |
Receive signal phase - Center freq
455 kHz (BNC |
|
CHARGE
(J5) |
Battery charge pack |
|
USED
BY ....
OCEANEERING
INTERNATIONAL
U.S.
NAVAL WARFARE CENTER, KEYPORT
U.
S. GEOLOGICAL SURVEY
STOLT
COMEX
.
. . . . AND OTHERS
|
|